Contattori

AF750-30-11 100-250V 50/60Hz / 100-250V DC

 
 
 
 Loading Images..
General Information
Extended Product Type:
AF750-30-11 100-250V 50/60Hz / 100-250V DC
Product ID:
1SFL637001R7011
EAN:
7320500217702
Catalog Description:
AF750-30-11 100-250V 50/60Hz / 100-250V DC Contactor
Long Description:
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC
Categories
    Products»
  • Prodotti di bassa tensione
  • »
  • Prodotti per l'industria
  • »
  • Contattori
  • »
  • Contattori
 
Ordering
EAN:
7320500217702
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Dimensions
Product Net Width:
210.0 mm
Product Net Depth:
242.0 mm
Product Net Height:
283.0 mm
Product Net Weight:
15.000 kg
Container Information
Package Level 1 Units:
1 piece
Package Level 1 Width:
290 mm
Package Level 1 Length:
270 mm
Package Level 1 Height:
350 mm
Package Level 1 Gross Weight:
15 kg
Package Level 1 EAN:
7320500217702
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Rated Operational Voltage:
Main Circuit 1000 V
Rated Frequency (f):
Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A
Rated Operational Current AC-1 (Ie):
(690 V) 55 °C 875 A
(690 V) 40 °C 1050 A
(1000 V) 40 °C 1000 A
(1000 V) 55 °C 875 A
(690 V) 70 °C 720 A
(1000 V) 70 °C 720 A
Rated Operational Current AC-3 (Ie):
(1000 V) 55 °C 300 A
(690 V) 55 °C 650 A
(415 V) 55 °C 750 A
(220 / 230 / 240 V) 55 °C 750 A
(440 V) 55 °C 750 A
(380 / 400 V) 55 °C 750 A
(500 V) 55 °C 750 A
Rated Operational Power AC-3 (Pe):
(500 V) 520 kW
(690 V) 600 kW
(220 / 230 / 240 V) 220 kW
(380 / 400 V) 400 kW
(440 V) 450 kW
(415 V) 425 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
Short-Circuit Protective Devices:
gG Type Fuses 1000 A
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Maximum Electrical Switching Frequency:
AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 60 cycles per hour
Rated Operational Current DC-1 (Ie):
(850 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie):
(850 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie):
(850 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Vita meccanica:
3 million
Maximum Mechanical Switching Frequency:
300 cycles per hour
Limiti di funzionamento della bobina second:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc):
60 Hz 100 … 250 V
50 Hz 100 … 250 V
DC Operation 100 … 250 V
Coil Consumption:
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A
Holding at Max. Rated Control Circuit Voltage DC 5 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Operate Time:
Between Coil Energization and NO Contact Closing 50 ... 120 ms
Between Coil De-energization and NO Contact Opening 53 ... 73 ms
Between Coil De-energization and NC Contact Closing 50 ... 70 ms
Between Coil Energization and NC Contact Opening 45 ... 115 ms
Connecting Capacity-Main Circuit:
Rigid Al-Cable 3x185 mm²
Bar 52 mm
Rigid Cu-Cable 300 mm²
Connecting Capacity-Auxiliary Circuit:
Solid 2x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 1x1…4 mm²
Flexible 1x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Environmental
Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay (0.85 - 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 - 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Shock Direction: A 5 g
Shock Direction: C2 5 g
Shock Direction: C1 5 g
Shock Direction: B2 5 g
Shock Direction: B1 5 g
RoHS Status:
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 900 A
Horsepower Rating UL/CSA:
(208 V AC) Three Phase 250 Hp
(440 ... 480 V AC) Three Phase 600 Hp
(550 ... 600 V AC) Three Phase 700 Hp
(220 ... 240 V AC) Three Phase 300 Hp
(200 V AC) Three Phase 250 Hp
Certificates and Declarations (Document Number)
BV Certificate:
CB Certificate:
CCC Certificate:
CSA Certificate:
Declaration of Conformity - CE:
DNV Certificate:
GL Certificate:
LOVAG Certificate:
LR Certificate:
RINA Certificate:
RoHS Information:
Classifications
E-nummer:
3228365
ETIM 5.0:
EC000066 - Magnet contactor, AC-switching
UNSPSC:
39121529